Jump to:

Product Design

Ultrasonic Generation of An Aqueous Nicotine Aerosol for Subjective Testing

Date: 02 Apr 1991
Length: 18 pages
2020126835-2020126852
Jump To Images
snapshot_pm 2020126835-2020126852

Abstract

Proposes changes to nicotine aerosol pH may affect subjective responses of impact and physiology. Outlines research plans to generate aerosol nicotine at controlled pH, describes the aerosol generator, includes schematics and states the aerosol composition is the same as aqueous. Indicates the nicotine concentration and pH can be adjusted, lists materials and methods and compares the physical characteristics of ultrasonic aerosol to cigarette smoke. Concludes an aerosol generation system for testing aqueous nicotine has been developed, the test protocol is refined and other substances may be tested using this protocol.

Fields

Author
Lipowicz, P.J.
Hypothesis
Free Nicotine
Toxicity and consumer intake
Development of scientifically valid procedures for measuring biological activity and neurological effects of nicotine and smoke constituents.
Nicotine transport, transfer, and uptake
Design changes which alter nicotine delivery or effect how the product causes and maintains dependence, including transfer of nicotine from tobacco to smoke, and uptake into the body.
Measuring human smoking behavior
Measuring the effects of changes in human smoking behavior on intake of nicotine and smoke constituents.
Keyword
Acidity (Low pH)
Aerosol
Bound nicotine (Protonated or ionized nicotine)
Delivery modification
Depth of inhalation
Dose-response
Free nicotine (Unprotonated or unionized nicotine)
Human testing
Impact (Throat grab)
Mouth feel (Mouthfull)
Nicotine delivery (Smoke nicotine or nicotine yield)
Nicotine manipulation
Per puff delivery
Per puff tar, per puff nicotine, and per puff CO
Puff volume (Puff amount)
Sensory response
Smoke Constituent
Nicotine
Design Component
Nicotine content (Tobacco nicotine content)
Total nicotine in the unburnt tobacco rod
Nicotine transfer efficiency (NTE)
Named Organization
Devilbiss
Technology/Method
Aqueous nicotine aerosol
Subject
Pressure Drop (Design)
aerosol (technology)
Experimental Technology (Technology)
nicotine technology
Particle Size (Technology)
pH Manipulation (Technology)
Puff Parameters (Measures)
Effects—Smoking Behavior (Effects)
Test/Inhalation (Testing)

Document Images

Text Control

Highlight Text:

OCR Text Alignment:

Image Control

Image Rotation:

Image Size:

Page 1: jtj88e00 Log in for more options!
ULTRASONIC GENE ZATION OF AN AQUEOUS NICOTINE AEROSOL FOR SUBJECTIVE TESTING Peter J. Lipowicz 2 April 1991
Page 2: jtj88e00 Log in for more options!
HYPOTHESIS: SUBJECTIVE RESPONSE TO NICOTINE AEROSOL CAN BE ALTERED BY CHANGING AEROSOL PH • Impact • Physiological response • Protonated nicotine vs. basic nicotine
Page 3: jtj88e00 Log in for more options!
RESEARCH PLAN • Generate nicotine aerosol at controlled~ pH • Measure subjective response with panelists • Determine validity of hypothesis • Determine applicability of hypothesis
Page 4: jtj88e00 Log in for more options!
CHARACTERISTICS OF THE IDEAL AEROSOL GENERATOR • Subjectively neutral matrix • Controllable and sufficient nicotine concentration • Controllable aerosol pH • Steady and reproducible output • Amenable to panelist testing
Page 5: jtj88e00 Log in for more options!
THE ULTRASONIC AEROSOL GENERATOR • Generates aqueous solution • Aerosol composition is same as solution composition • Nicotine concentration of solution can be varied • pH of solution can be adjusted with addition of acid • Can generate high concentrations, • Compact commercial units available
Page 6: jtj88e00 Log in for more options!
G.n4rator R.stfrotr (E): G.ys.r(0)
Page 7: jtj88e00 Log in for more options!
2020j26841
Page 8: jtj88e00 Log in for more options!
ISSUES IN THE DEVELOPMENT OF THE TEST PROTOCOL • Nicotine level -- 20'to 30 ug per puff • Acid to adjust pH -- phosphoric acid • Measurement of aerosol pH -- pH paper • Isotonicity of solution -- not controlled • Sterility of solution -- filter sterilized • Sterility of generator -- autoclaved'~ • Nicotine concentration in aerosol -- spectrophotometry • Venting excess aerosol -- installed hood in Frank Gullotta's laboratory • Sampling prodecure • Reproducibility of aerosol production • Physical nature of aerosol
Page 9: jtj88e00 Log in for more options!
REQUIREMENTS OF SAMPLING PROCEDURE • Simplicity • Delivers controlled volume of aerosol • Similarity to cigarette -- inhalation by puffs -- puff volume -- pressure drop -- size of mouth end
Page 10: jtj88e00 Log in for more options!
STABILITY AND REPRODUCIBILITY OF AEROSOL OUTPUT • Required so that nicotine level can be controlled • Medium rate ( 1 g/min ) is not reproducible -- varies for different aqueous solutions • High rate(4.5 g/min ) isbetter-- less affected by solution composition

Text Control

Highlight Text:

OCR Text Alignment:

Image Control

Image Rotation:

Image Size: